Lac Alka Liquid HD 25 Ltrs

   

In Stock

Well balanced alkaline cleaner. It is free hydrocarbon solvents.Gentle & sutable for tank cleaning operation. A very strong alkaline cleaner, which can be used to soften up / remove baked on drying oils and also used after animal and vegetable oils, fish

Compare
SKU: RXSOL-20-2015-025 Category:
   

Description

Well balanced heavy duty alkaline tank cleaner. A very strong alkaline lac cleaner, which can be used to soften up and cleaning of drying / non drying fats oils and also used after animal and vegetable oils, fish oils, tall oils, tung oil etc. It is free hydrocarbon solvents.Gentle & sutable for tank cleaning operation.   It’s natural based detergent product have an exceptional solvency power on soil & oily  matter. It is free from Hydrocarbon solvents , Biodegradable and minimizes the extreme hazards to personnel in handling materials.

We are LAC Alkaleen liquid Tank Cleaners manufacturers in india. And holding no-1 position for LAC Alkaleen liquid Tank Cleaners suppliers in kandla, mundra, chennai, ennore, vizag, kakinada, jnpt, manglore, kolkata, haldia, paradip, dubai, fujairah, sharjah.  Alkaleen Liquid Heavy Duty concentration makes surface clean easily and effectively.

Application:

It can be used as a general purpose cleaner to remove oil and grease deposits.First of all flush the system with cold water to prevent evaporation rates and polymerization then the most economical method of using RXSOL-20-2015-025 is by direct injection followed by recirculation washing, using tank cleaning machines. Spraying Method  – Using LAC as delivered in drums, spray onto areas where residue remains following rough washing leave for 10-45 minutes (but do not allow to dry), then butterworth at maximum pressure and warm water 60oC for at least 3 hours, checking that there is no foam remaining in the final stages.  Inspects tanks(s) and if desired result has been achieved fresh water rinse and dry.

** Make sure to take all safety precautions are followed when handling / spraying RXSOL-20-2015-025

Injection Method – not applicable.

Dose:

Refer to technical datasheet

Note:

Re-circulation Method :
Fill tank with fresh water and heat up to warm 50 oC .IF a drop line is available on the tank line system, then start to circulate the water and add the required amount of Caustic flakes and LAC to make a 2.5% solution.  A stronger solution can be made, but be advised that too much Caustic and too high temperature will result in white powder all over the tank.  Under normal circumstances, between 2.5% and 4.5% will be sufficient strength.  If there is no drop line, then lower butterworth hoses into the tank from the pump stack header without machines attached and circulate through these hoses while you fill the solution material.

* Use a strainer at the pump stack when circulating any solution.*
  Tank Lining – Stainless / Epoxy / Phenolic

Additional information

MSDS

<p>
<img alt="" src="http://content.rxmarine.com/images/msds/header/heading1.png&quot; style="width: 825px; height: 46px" /></p>
<table border="0" cellpadding="1" cellspacing="1" style="width: 635px; height: 50px">
<tbody>
<tr>
<td style="width: 20%">
Product Name                </td>
<td style="width: 70%">
<strong><span style="background-color: rgb(255,255,255)"><strong><font color="#000000">RXSOL-20-2015-025</font></strong></span></strong></td>
</tr>
<tr>
<td>
Product Type</td>
<td>
Lac Alka Liquid HD  <strong>Industrial cleaner </strong></td>
</tr>
</tbody>
</table>
<p>
<strong>Company Details:</strong><br />
RX MARINE INTERNATIONAL<br />
105, A wing , BSEL , TECH PARK.<br />
VASHI ,NEW BOMBAY 400703 INDIA</p>
<table border="0" cellpadding="1" cellspacing="1" style="width: 635px; height: 61px">
<tbody>
<tr>
<td style="width: 20%">
Phone</td>
<td style="width: 70%">
+91 22 65113333 / 5555 / 9999 / 27611360</td>
</tr>
<tr>
<td>
Fax</td>
<td>
+91 22 2781 1318 :::AOH :0091 9821214367</td>
</tr>
<tr>
<td>
Email</td>
<td>
<strong><a href="mailto:mail@rxmarine.com">mail@rxmarine.com</a></strong></td>
</tr>
</tbody>
</table>
<p>
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading2.png&quot; style="width: 820px; height: 46px" width="849" /></p>
<p style="text-align: justify;">
SURFACTANT ( ANIONIC & NON-IONIC), LAB, Sodium hydroxide And Butyl Cellosolve Strong alkaline cleaner Declaration according to recommendation 89/542/EEG.</p>
<p>
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading3.png&quot; style="width: 816px; height: 46px" width="851" /></p>
<table border="0" cellpadding="0" cellspacing="1" style="width: 630px" width="630">
<tbody>
<tr>
<td style="width: 149px; height: 10px">
<p>
Environmental Hazards</p>
</td>
<td style="width: 479px; height: 10px">
<p>
None</p>
</td>
</tr>
<tr>
<td style="width: 149px; height: 16px">
<p>
Human Health  Hazards</p>
</td>
<td style="width: 479px; height: 16px">
<p>
Moderates</p>
</td>
</tr>
</tbody>
</table>
<p>
R 35:Causes skin burning effects<br />
                                                                                                   <img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading4.png&quot; style="width: 819px; height: 46px" width="852" /></p>
<table border="0" cellpadding="0" cellspacing="1" style="width: 630px" width="635">
<tbody>
<tr>
<td style="width: 145px; height: 4px">
<p>
Inhalatin</p>
</td>
<td style="width: 488px; height: 4px">
<p>
Harmful,. supply or remove to fresh air and seek medical advice attention.</p>
</td>
</tr>
<tr>
<td style="width: 145px">
<p>
Skin Contact</p>
</td>
<td style="width: 488px">
<p>
Rinse with running water and soap. Skin care. Remove contaminated clothes.</p>
</td>
</tr>
<tr>
<td style="width: 145px; height: 4px">
<p>
Eye  Contact</p>
</td>
<td style="width: 488px; height: 4px">
<p>
Flush with running water for at least 15 minutes Immediately.</p>
</td>
</tr>
<tr>
<td style="width: 145px">
<p>
Ingestion</p>
</td>
<td style="width: 488px">
<p>
Vomiting is dangerous , seek medical attention.</p>
</td>
</tr>
</tbody>
</table>
<p>
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading5.png&quot; style="width: 816px; height: 46px" width="849" /></p>
<p>
<span style="font-size: 14px">Non Combustible Porduct </span></p>
<table border="0" cellpadding="0" cellspacing="1" style="width: 630px" width="635">
<tbody>
<tr>
<td style="width: 145px; height: 4px">
<p>
<span style="font-size: 14px">Suitable</span></p>
</td>
<td style="width: 488px; height: 4px">
<p>
<span style="font-size: 14px">N.A. can use  foam dry Co2 , water-spray.</span></p>
</td>
</tr>
<tr>
<td style="width: 145px; height: 4px">
<p>
<span style="font-size: 14px">Not suitable</span></p>
</td>
<td style="width: 488px; height: 4px">
<p>
<span style="font-size: 14px">Not applicable</span></p>
</td>
</tr>
<tr>
<td style="width: 145px; height: 4px">
<p>
<span style="font-size: 14px">Special</span></p>
</td>
<td style="width: 488px; height: 4px">
<p>
<span style="font-size: 14px">Not applicable</span></p>
</td>
</tr>
<tr>
<td style="width: 145px">
<p>
<span style="font-size: 14px">Protection of fire Fighter</span></p>
</td>
<td style="width: 488px">
<p>
<span style="font-size: 14px">Not applicable  </span></p>
</td>
</tr>
</tbody>
</table>
<p>
Special protective equipment for fire-fighters:  Wear protective equipment.<br />
<br />
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading6.png&quot; style="width: 819px; height: 46px" width="851" /></p>
<table border="0" cellpadding="0" cellspacing="1" style="width: 630px" width="635">
<tbody>
<tr>
<td style="width: 145px; height: 4px">
<p>
Enviromentel Precaution</p>
</td>
<td style="width: 488px; height: 4px">
<p style="text-align: justify">
Direct flow into drainage system, surface or ground water is  prohibited.</p>
</td>
</tr>
<tr>
<td style="width: 145px">
<p>
Cleaning Method</p>
</td>
<td style="width: 488px">
<p style="text-align: justify">
Flush Spill Area with Water and remove with liquid-absorbing material like foam sand, sawdust etc..</p>
</td>
</tr>
</tbody>
</table>
<p>
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading7.png&quot; style="width: 818px; height: 46px" width="837" /></p>
<table border="0" cellpadding="0" cellspacing="1" style="width: 630px" width="626">
<tbody>
<tr>
<td style="width: 145px; height: 4px">
<p>
<span style="font-size: 14px">Condition to Avoid</span></p>
</td>
<td style="width: 479px; height: 4px">
<p>
<span style="font-size: 14px">Non-flammable but avoid direct heating</span></p>
</td>
</tr>
<tr>
<td style="width: 145px; height: 4px">
<p>
<span style="font-size: 14px">Materials  to Avoid</span></p>
</td>
<td style="width: 479px; height: 4px">
<p>
<span style="font-size: 14px">Do not subject to Acidic / Oxidizing Agents</span></p>
</td>
</tr>
<tr>
<td style="width: 145px">
<p>
<span style="font-size: 14px">Handling</span></p>
</td>
<td style="width: 479px">
<p>
<span style="font-size: 14px">Keep Container Tightly Closed</span></p>
</td>
</tr>
</tbody>
</table>
<p style="text-align: justify;">
<span style="font-size: 14px">Note</span>:Eyewash facilities require at workplace The product causes corrosion on skin and mucous membranes Pl. Note that In case of discharge of acidic or alkaline products into the sewerage system the pH must be in the range of 6-10 since higher or lower pH values may damage the sewerage system or impair biological dosage treatment plants. So that for maintaining pH we have to add acidic / basic medium neutaliser . For example if pH is less than 6 basic neutraliser is required and if pH is more than 10 acidic nature neutraliser is required. For details of any guideline pl. Visit our technical website <a href="http://www.rxmarine.com/">www.rxmarine.com</a><br />
•Dilute in water (always use plastic jar and RXSOL should be added to  water  never add water to RXSOL.)<br />
 <br />
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading8.png&quot; style="width: 822px; height: 46px" width="851" /></p>
<p>
<span style="font-size: 14px">Personal protection : </span></p>
<table border="0" cellpadding="0" cellspacing="1" style="width: 630px" width="626">
<tbody>
<tr>
<td style="width: 145px; height: 3px">
<p>
<span style="font-size: 14px">Respiratory System Protection </span></p>
</td>
<td style="width: 479px; height: 3px">
<p>
<span style="font-size: 14px">Approved respirator must be worn when spraying</span></p>
</td>
</tr>
<tr>
<td style="width: 145px; height: 4px">
<p>
<span style="font-size: 14px">Eye Protection</span></p>
</td>
<td style="width: 479px; height: 4px">
<p>
<span style="font-size: 14px">Cear eye protection (on possibility of contact )</span></p>
</td>
</tr>
<tr>
<td style="width: 145px">
<p>
<span style="font-size: 14px">Hand protection</span></p>
</td>
<td style="width: 479px">
<p>
<span style="font-size: 14px">Cear PVC chemical resistance protective glove</span></p>
</td>
</tr>
</tbody>
</table>
<p>
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading9.png&quot; style="width: 818px; height: 46px" width="851" /></p>
<p>
 Product Properties:</p>
<table border="0" cellpadding="0" cellspacing="1" style="width: 630px" width="635">
<tbody>
<tr>
<td style="width: 145px; height: 4px">
<p>
Appearance</p>
</td>
<td style="width: 488px; height: 4px">
<p>
Pale clear liquid   </p>
</td>
</tr>
<tr>
<td style="width: 145px; height: 4px">
<p>
Density</p>
</td>
<td style="width: 488px; height: 4px">
<p>
In g/cm3 at 20°C: 1.21  </p>
</td>
</tr>
<tr>
<td style="width: 145px; height: 4px">
<p>
Compatibility    </p>
</td>
<td style="width: 488px; height: 4px">
<p>
 </p>
</td>
</tr>
<tr>
<td style="width: 145px; height: 4px">
<p>
Metal</p>
</td>
<td style="width: 488px; height: 4px">
<p>
No known effect</p>
</td>
</tr>
<tr>
<td style="width: 145px; height: 4px">
<p>
Rubber</p>
</td>
<td style="width: 488px; height: 4px">
<p>
No known effect   </p>
</td>
</tr>
<tr>
<td style="width: 145px; height: 4px">
<p>
pH  </p>
</td>
<td style="width: 488px; height: 4px">
<p>
Alkaline ( 13 )</p>
</td>
</tr>
<tr>
<td style="width: 145px; height: 4px">
<p>
Flashpoint</p>
</td>
<td style="width: 488px; height: 4px">
<p>
Not Applicable  </p>
</td>
</tr>
<tr>
<td style="width: 145px; height: 4px">
<p>
Solubility</p>
</td>
<td style="width: 488px; height: 4px">
<p>
100% soluble in water </p>
</td>
</tr>
<tr>
<td style="width: 145px">
<p>
Packaging </p>
</td>
<td style="width: 488px">
<p>
Size (in Litres)</p>
</td>
</tr>
</tbody>
</table>
<p>
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading10.png&quot; style="width: 822px; height: 46px" width="851" /></p>
<table border="0" cellpadding="0" cellspacing="1" style="width: 635px" width="635">
<tbody>
<tr>
<td style="width: 145px">
<p>
Hazardous Decomposition Products</p>
</td>
<td style="width: 488px">
<p style="text-align: justify">
Do not occur if stored and used as directed. n FIRE combustion CO, CO2 , NH3 , SOX etc hazardous gas produced</p>
</td>
</tr>
</tbody>
</table>
<p>
NOTE : Avoid Contact With Acid</p>
<p>
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading11.png&quot; style="width: 826px; height: 46px" width="853" /></p>
<p>
<strong>  Comment – <span style="font-size: 14px"> </span></strong><span style="font-size: 14px">Not applicable , Emulsifies in water </span></p>
<p>
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading12.png&quot; style="width: 825px; height: 46px" width="848" /></p>
<p style="text-align: justify;">
<span style="font-size: 14px">95 % added surfactants are biodegradable as per by international regulation. This material must be disposed of with local national regulations.</span></p>
<p>
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading13.png&quot; style="width: 820px; height: 46px" width="852" /></p>
<p>
<span style="font-size: 14px">As per guideline of local rules and regulation and before disposal and neutralization pl. refer 07 article.</span></p>
<p>
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading14.png&quot; style="width: 819px; height: 46px" width="852" /></p>
<table border="0" cellpadding="1" cellspacing="1" style="width: 635px; height: 482px">
<tbody>
<tr>
<td colspan="5">
Proper Shipping Name</td>
</tr>
<tr>
<td>
UN</td>
<td>
 </td>
<td>
 </td>
<td>
 </td>
<td>
 </td>
</tr>
<tr>
<td>
 </td>
<td>
Proper Shipping Name</td>
<td colspan="3">
<p>
Sodium hydroxide, solution</p>
</td>
</tr>
<tr>
<td>
 </td>
<td>
UNNo.</td>
<td>
1824</td>
<td>
 </td>
<td>
 </td>
</tr>
<tr>
<td>
 </td>
<td>
Hazard Class</td>
<td>
8</td>
<td>
PackingGroup</td>
<td>
II</td>
</tr>
<tr>
<td colspan="5">
Road/Rail(ADR/RID)</td>
</tr>
<tr>
<td>
 </td>
<td>
Proper Shipping Name</td>
<td colspan="3">
<p>
Sodium hydroxide, solution</p>
</td>
</tr>
<tr>
<td>
 </td>
<td>
ADR UN No.</td>
<td>
1824</td>
<td>
 </td>
<td>
 </td>
</tr>
<tr>
<td>
 </td>
<td>
ADR Hazard Class</td>
<td>
8</td>
<td>
Tremcard</td>
<td>
<p>
80S1824</p>
</td>
</tr>
<tr>
<td colspan="5">
<p>
Sea(IMDG)</p>
</td>
</tr>
<tr>
<td>
 </td>
<td>
Proper Shipping Name</td>
<td colspan="3">
<p>
Sodium hydroxide, solution</p>
</td>
</tr>
<tr>
<td>
 </td>
<td>
IMDG UN No.</td>
<td>
1824</td>
<td>
 </td>
<td>
 </td>
</tr>
<tr>
<td>
 </td>
<td>
IMDG Hazard Class.</td>
<td>
8</td>
<td>
IMDG Pack Group.</td>
<td>
II</td>
</tr>
<tr>
<td>
 </td>
<td>
IMDG EmS</td>
<td>
F-A, S-A</td>
<td>
IMDG subrisk</td>
<td>
<p>
N/A</p>
</td>
</tr>
<tr>
<td>
 </td>
<td>
IMDG Labels</td>
<td>
<p>
8</p>
</td>
<td>
IMDG Flash point</td>
<td>
<p>
N/A</p>
</td>
</tr>
<tr>
<td colspan="5">
<p>
Air(ICAO/IATA)</p>
</td>
</tr>
<tr>
<td>
 </td>
<td>
Proper Shipping Name</td>
<td colspan="3">
<p>
Sodium hydroxide, solution</p>
</td>
</tr>
<tr>
<td>
 </td>
<td>
ICAO Un No.</td>
<td>
1824</td>
<td>
 </td>
<td>
 </td>
</tr>
<tr>
<td>
 </td>
<td>
ICAO Hazard Class</td>
<td>
8</td>
<td>
ICAO Packing Group.</td>
<td>
II</td>
</tr>
<tr>
<td>
 </td>
<td>
ICAO subrisk</td>
<td>
<p>
N/A</p>
</td>
<td>
ICAO Labels</td>
<td>
<p>
8, CAO</p>
</td>
</tr>
<tr>
<td>
 </td>
<td>
ICAO Flashpoint</td>
<td>
N/A</td>
<td>
 </td>
<td>
 </td>
</tr>
<tr>
<td colspan="5">
<p>
DOT/ CFR (US Department of Transportation)</p>
</td>
</tr>
<tr>
<td>
 </td>
<td>
DOT Proper Shipping Name</td>
<td colspan="3">
<p>
Sodium hydroxide, solution</p>
</td>
</tr>
<tr>
<td>
 </td>
<td>
Hazardous Material</td>
<td>
<p>
Sodium hydroxide</p>
</td>
<td>
 </td>
<td>
 </td>
</tr>
<tr>
<td>
 </td>
<td>
Hazard Class</td>
<td>
8</td>
<td>
Identification Number</td>
<td>
UN 1824</td>
</tr>
<tr>
<td>
 </td>
<td>
Product RQ (lbs)</td>
<td>
3640</td>
<td>
DOT subrisk</td>
<td>
N/A</td>
</tr>
<tr>
<td>
 </td>
<td>
DOT Labels</td>
<td>
8</td>
<td>
DOTFlashpoint </td>
<td>
<p>
N/A</p>
</td>
</tr>
</tbody>
</table>
<p style="text-align: justify">
<br />
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading15.png&quot; style="width: 814px; height: 46px" width="852" /><br />
<br />
 <span style="font-size: 14px">Classification and labelling according to Chemicals Hazard Information and Packaging Regulations (CHIP). Symbols of danger:- C Corrosive </span></p>
<table border="0" cellpadding="0" cellspacing="1" style="width: 630px" width="632">
<tbody>
<tr>
<td style="width: 145px; height: 10px">
<p>
<span style="font-size: 14px">R phrases</span></p>
</td>
<td style="width: 485px; height: 10px">
<p>
<span style="font-size: 14px">R 35: Causes severe burns</span></p>
</td>
</tr>
<tr>
<td style="width: 145px">
<p>
<span style="font-size: 14px">S-phrases</span></p>
</td>
<td style="width: 485px">
<p style="text-align: justify;">
<span style="font-size: 14px">S2: Keep out of reach of children S26: In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. S28: After contact with skin, wash immediately with plenty of water. S37/39: Wear suitable gloves and eye/face protection.</span></p>
</td>
</tr>
</tbody>
</table>
<p style="text-align: justify">
<img alt="" height="46" src="http://content.rxmarine.com/images/msds/header/heading16.png&quot; style="width: 812px; height: 46px" width="851" /><br />
<br />
<span style="font-size: 14px"><span style="font-size: 12px">This information is based on our current level of knowledge and relates to the product in the state in which it is delivered. It is intended to describe our product from the point of view of safety requirements and is not intended to guarantee any particular properties      </span>                                                               </span><br />
 </p>

Technical Bulletin

Have a Question? Submit it here!

*
*

*

Online Inquiry
Loading...
Show Buttons
Hide Buttons