Hardness Phosphate Control RXSOL-50-5006-025
Boiler Chemicals

Hardness Phosphate Control

Part No. RXSOL-50-5006-025

Phosphate Boiler Water Treatment Hardness Control is a white dry powder Phosphate Boiler Water Treatment product is used for the reduction of hardness in boilers. Hardness Control is highly soluble in water and It will precipitate calcium hardness

Price, pack size and lead time on request. Email suratchemical @ gmail.com or call +91 80699 76664.

Also known as
Green HC, Phosphate Control Boiler Water Treatment Chemicals, HCT 103 Norchem, Ferrolix L40, Ferrolix L40A, DM-527, Fostreat, ADJUNCT Hardness Phosphate Control 25 Kgs Powder Pack
Supplied from
Bhestan, Surat, Gujarat
Supply locations
Hardness Phosphate Control is available in several packaging sizes at several stock points like Fujairah, Dubai, Muscat, Barka, Nairobi Kenya, Uganda, Africa Canada, Bristish Columbia, Mumbai, Thane, Kandla, Gandhidham, Vizag, Vishakhapatnam, Ennore, Chennai, Kolkata.

Description

Hardness Control is a white dry powder Phosphate Boiler Water Treatment product used for the reduction of hardness in boilers. Hardness Control is highly soluble in water and It will precipitate calcium hardness as a non-adherent sludge.

Remarks

Phosphate/pH relationship recommended to control boiler corrosion. Different forms of phosphate consume or add caustic as the phosphate shifts to the proper form. For example, addition of monosodium phosphate consumes caustic as it reacts with caustic to form disodium phosphate in the boiler water according to the following reaction:

NaH2PO4 + NaOH ® Na2HPO4 + H2O
monosodium phosphate   sodium hydroxide   disodium phosphate   water


Conversely, addition of trisodium phosphate adds caustic, increasing boiler water pH:

Na3PO4 + H2O ® Na2HPO4 + NaOH
trisodium phosphate   water   disodium phosphate   sodium hydroxide
 
Tag Identification

How to extend boiler life?

Hardness Phosphate Control Boiler Treat is a chemical formulation developed for steam boiler water treatment.

Hardness Phosphate Control Boiler Treat is formulated as a corrective phosphate for boiler water treatment following primary decarbonization through ion exchange, as well as for the treatment of non-decarbonized feed water in steam boilers. It is intended for use with soft to medium-hard water, provided that the total hardness does not exceed 2.7 mol/m³ (270 ppm as CaCO₃).

Due to its stabilizing properties, Hardness Phosphate Control Boiler Treat protects feed lines against scale formation. The sludge formed inside the boiler undergoes flocculation, resulting in a loose, flaky structure that can be easily discharged through blowdown. In addition, the boiler surfaces are safeguarded against corrosion, and continuous application helps reduce existing scale deposits.

Oxygen-binding components react with residual dissolved oxygen present in feed water and boiler water, thereby minimizing corrosion risks. The formulation also contains antifoaming agents that prevent foam formation in highly alkaline conditions or when boiler water salt concentrations are elevated.

Hardness Phosphate Control Boiler Treat is non-volatile.

The product should be applied after primary decarbonization by ion exchange and is suitable for all types of steam boilers, excluding disposable heating boilers. A 1–2% solution is dosed to maintain 10–15 ppm P₂O₅ in boiler water. Typically, a dosage of 5–6 g/m³ of product is sufficient for feed water. If insufficient thermal deaeration results in oxygen levels exceeding 2 mg/l, it is recommended to use a dedicated RXSOL OxyControl containing a higher concentration of oxygen-binding agents.

For feed water treatment, the solution is continuously dosed at 1–2% to maintain 10–15 ppm P₂O₅ in boiler water. Generally, when total hardness is approximately 20 ppm (as CaCO₃), a dosage of 10–15 g of product per cubic meter of feed water is required. The precise dosage depends on both total and carbonate hardness and should be determined with support from technical specialists. If the feed water is slightly alkaline, an alkaline-adjusted variant of Hardness Phosphate Control Boiler Treat should be used.

Note

Benefit and Features

  • Highly active phosphate based compound, economical in use.
  • Easily dissolved in water for dosing.
  • Scale problems due to calcium are eliminated.
  • Maintains sludge in a non-adherent state for ease of blow down.
  • Simple test to determine level of treatment.
  • Can be used for boilers of all pressures.
    Rxsol Hardness Control does not influence the alkalinity in the system

RXSOL brand is well known name for Hardness Phosphate control manufacturer, Exporter and supplier in Mumbai, Chennai, Kolkata, Vizag, Goa, Kochin, Manglore, Kandla, Gandhidham, Fujairah, Dubai, Sharjah, Uae, Gulf Middle East

Technical specifications

Sampling And Testing

A sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Rxsol Hardness Test Kit instructions and fill the Boiler Water Log Form according to result results. It is important that regular testing is carried out to ensure levels of treatment are correct.

Physical Properties :

Appearance        :White powder
Corrosive action  :None
pH 1% solution   :8.8
Flash point         :None

Application

Hardness Control is formulated to form a precipitate with calcium ions which will not adhere to metal surfaces but are in a form suitable for blowdown.

Used for boilers and water softening.

Formation of Calcium Sulfate is main cause for SCALE formation :::

The principal problem potential posed by sulfate ions in water is the possibility of calcium sulfate scale formation.  Precipitation of calcium sulfate can occur when high concentrations of both calcium and sulfate exist simultaneously.  There are three primary areas of water treatment in which calcium sulfate precipitation may occur boilers, cooling systems, and ion exchangers operating in the hydrogen or acid mode.

In boilers, calcium sulfate scale formation has been reduced to a minimum by modern treatment practices.  The low hardness levels largely preclude calcium sulfate boiler scale.    By contrast, cooling systems are subject to calcium sulfate scale deposition because the makeup is usually not treated for hardness removal.  Cooling water is usually treated with sulfuric acid for pH control, and the makeup is cycled, i.e. concentrated.  Calcium sulfate scale deposition can  result unless the cycles of concentration are properly controlled in conjunction with the proper use of scale control chemicals.  Cation ion exchangers regenerated with sulfuric acid also can pose a major calcium sulfate problem. Calcium sulfate precipitation can be avoided by controlling the acid concentration and the flow rate through the exchanger.  

Sulfate content can be calculated in Laboratory by using this method ::: http://rxmarine.com/SULFATE-TEST-KIT

Industrial usage

#BoilerWaterTreatment_HardnessCONTROL
#BoilerWaterTreatmentCHEMICAL_SUPPLIER
#BoilerWaterTreatment_supplierUAEdubai
#BoilerWaterTreatment_supplierOMANmuscat

A precipitant designed to eliminate scale deposits and lower the hardness of water in boilers with working pressure up to 60 bars.

It is used in conjunction with alkaline liquid to prevent calcium scale deposits. Both products are used in our standard boiler water treatment programs for low-pressure boiler systems (0-32 bar) and medium-pressure steam propulsion vessels (32-60 bar).

Hardness Phosphate Control
Role of phosphate in boiler water
Trisodium phosphate in boiler water
Trisodium phosphate dosing boiler drum
boiler water hardness limit
Boiler scale formation
Effect of phosphate in boiler water
Boiler phosphate control

Phosphate/pH relationship recommended to control boiler corrosion. Different forms of phosphate consume or add caustic as the phosphate shifts to the proper form. For example, addition of monosodium phosphate consumes caustic as it reacts with caustic to form disodium phosphate in the boiler water according to the following reaction:

NaH2PO4 + NaOH ® Na2HPO4 + H2O
monosodium phosphate   sodium hydroxide   disodium phosphate   water


Conversely, addition of trisodium phosphate adds caustic, increasing boiler water pH:

Na3PO4 + H2O ® Na2HPO4 + NaOH
trisodium phosphate   water   disodium phosphate   sodium hydroxide
 

Dosage

For optimum results dose Hardness Control direct to the boiler via the bypass pot-feeder. The dry powder should be dissolved in hot water (50°C) at a ratio of 1 part powder to twenty parts condensate (e.g. 500 grams/10 litres). Ensure that treatment is fully dissolved before dosing.


This  treatment dosed at 1.49 grams per ton of distilled water provides 1.0 ppm phosphate.

Feed Points: Dose with other BOILER CHEMICAL/alkaline liquid by diluting withcondensate and feed directly into the system drum (below the water level) using a bypass pot feeder. For low-pressure boilers, It may be dosed to the hotwell or condensate return tank, although this is not the preferred method.

 

Dosage and control

 

Phophate test result in pPM PO4

 

 Pressure

 0 - 10

10 - 20

20 - 30

30 - 40

40 - 50

> 50

 Control range

 0-40 Bar
0-588 PSI

 23

11.5 

Satisfactory

Satisfactory

Blow Down

 20-50

41-60 Bar
589-880 PSI 

 17

 5.5

Satisfactory

Blow Down

Blow Down

  15-30

 > 60 Bar
> 880 PSI

 5.5

 Satisfactory

Satisfactory

Blow Down

Blow Down

 10-25

Select row on righthand side for applicable pressure range. Compare test result with comment in table and dose stated amount of product per ton boiler water volume.

These are recommended values based on experience and are in no way intended to replace the boiler manufacturer's specifications or company regulations.


 

Usages

Application of RXSOL's boiler water internal treatment chemicals is a significant contributor in the fight to control deposit forming contaminants, maintain clean heat transfer surfaces, ensure optimum efficiency, and prevent downtime. In addition, the benefits of internal boiler water treatment include:
Reduces deposition and potentially removes pre-existing scale
Reduces the probability of deposit-associated corrosion
Improves contaminant transport and reduces boiler sludge accumulation
Promotes clean heat transfer surfaces and enhances boiler efficiency
Control total cost of ownership by optimizing fuel and water consumption
Improves reliability and availability by minimizing tube failure and downtime

MSDS

Product Name : RXSOL-50-5006-025
Product Type : HARDNESS CONTROL 25 Kgs

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock points: Dubai, Muscat, Kenya, Uganda, Canada, Mumbai, Kandla, Kolkata, Vizag, Chennai

Phone : +91 22 65113333 / 5555 / 9999 / 27611360
Fax : +91 22 2781 1318 :::AOH :0091 9821214367
Email : mail@rxmarine.com

Chemica Name

Concentration

CAS Number

EC Number

R Phrases*

Symbols

SodiumHexameta Phosphate

60-90

10124-56-8

233-343-1

-

-

Monosodium Phosphate 10-20 .... ..... ..... ....
Proprietory Blend of Softner 20-30 ..... ...... ..... ....

*See Section 16

Odour

Odourless.

Appearance

powder, white, soluble in water.

Contact with eyes

Prolonged exposure may cause abrasive irritation of the eyes.

Contact with skin

In cases of severe exposure, irritation may develop.

Inhalation

Prolonged exposure may cause abrasive irritation of the mucous membranes.

Ingestion

The ingestion of significant quantities may cause gastro-intestinal disturbances.

Contact with skin

Wash affected area with plenty of soap and water

Contact with eyes

If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes Irrigate eyes thoroughly whilst lifting eyelids.When in doubt or symptoms persist, seek medical attention

Ingestion

Never give anything by mouth to an unconscious person.Give water or milk to drink.When in doubt or symptoms persist, seek medical attention

Inhalation

Remove patient to fresh air.Seek medical attention if irritation persists

General

In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45)

- Non-combustible solid
- Decomposition products may include phosphorous compounds
- Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions

Personal Precautions

Wear protective clothing as per section 8.Avoid raising dust.

Environmental Precautions

No special precautions are required for this product.

Clean Up Actions

Sweep or shovel-up spillage and remove to a safe place.Wash spill site with water and detergent.

Special Precautions

Wear protective clothing as per section 8.

Handling

The usual precautions for handling chemicals should be observed.

Storage

Keep only in the original container in a cool, well ventilated place (S3/9/49).

Exposure Limits

There are no recommended or established controls for this product.

Occupational exposure controls

Wear suitable dust mask e.g. to BS 2091.Wear suitable protective clothing, including eye/face protection and gloves (plastic or rubber are recommended).

gloves                   goggles                   suit                    no_smoking

Gloves                      Goggles                         Suit                        No_Smoking

Odour

Odourless

Appearance

powder, white, soluble in water

pH

6 at 1 % concentration

Vapour pressure

not known

Melting point

>600 °C at 760 mm /Hg - Water solubility ~100 g/l

Density

1100 kg/m3

Non-combustible solid

 

- This article is considered stable under normal conditions+9
- Avoid contact with moist air
- See Section 5

Toxicological information

LD50 (dermal) : 7250 mg/kg

Inhalation

May cause irritation

Contact with skin

In cases of severe exposure, redness and irritation may develop

Contact with eyes

May cause irritation

Ingestion

No effects for small dosage. Large dose effects not known
The ingestion of significant quantities may cause gastro-intestinal disturbances

Carcinogenicity

No evidence of carcinogenic effects

Ecotoxicity

Presents little or no hazard to the aquatic environment

Mobility

Completely soluble in water

Persistence and Biodegradability

Degrades by hydrolysis

Bioaccumulation Potential

Bioaccumulation is insignificant

Other Adverse Effects

No environmental problems are expected when the product is used / handled correctly. In its   intended use, the product will not be released into the environment.Presents little or no hazard to the environment.

Classification

EU Waste class

Disposal considerations

Do not discharge into drains or the environment, dispose to an authorised waste collection point Disposal should be in accordance with local, state or national legislation

- Not classified as hazardous for transport

Risk Phrases

Not applicable

Safety Phrases

Not applicable

The information provided about the product on this Safety Data Sheet has been compiled from knowledge of The individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product In terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The product is not sold as uitable for other applications - usage in such may cause risks not mentioned in this sheet. Do not use f or other Application without seeking advice from manufacturer This Safety Data Sheet is provided in compliance with The Dangerous Substances Directive (67/548/EEC) This Safety Data Sheet is provided in compliance with The Dangerous Preparations Directive (88/379/EEC) This Safety Data Sheet is provided in compliance with The Safety Data Sheets Directive (2001/58EC)

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Related information

Deposition and corrosion of boiler systems reduce efficiency, increase fuel and water consumption, and may lead to failures, which are a safety hazard, add maintenance costs and may impede production. RXSOL's  boiler water internal treatment programs provide highly effective protection against corrosion and scale formation to ensure optimum performance and availability of your steam system while reducing the total cost of ownership and environmental footprint through energy and water savings.

Better BOILER TREATMENT practices

It is used in conjunction with RXSOL pH Booster concentrated liquid to prevent calcium scale deposits. Both products are used in standard boiler water treatment programs for low pressure boiler systems (0-32 bar) and medium-pressure steam propulsion vessels (32-60 bar). They are also used for high pressure steam generating systems (60-84 bar). The use of Hardness Phosphate Control treatment in conjunction with RXSOL pH Booster concentrated alkaline liquid converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown.

Hashtags
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride
content

#HardnessPhosphateControl_supplier_in_Navlakhi

# HardnessPhosphateControl  _supplier_in_Okha

#  HardnessPhosphateControl  _supplier_in_Ankleshwar

#  HardnessPhosphateControl   _supplier_in_Bharuch

#  HardnessPhosphateControl  _supplier_in_Hazira

# HardnessPhosphateControl   _supplier_in_Surat

# HardnessPhosphateControl   _supplier_in_Gujarat