Corrosion Inhibitor Nitrite Borax based

Corrosion Inhibitor Nitrite Borax based
SKU
RXSOL-40-4023-020
Supply Location::
Locations

Corrosion Inhibitor Nitrite Borax based for cooling water circulation system manufacturer and supplier in Dubai, Nairobi, Mombasa, Kenya, Uganda, Mumbai, Kolkata, Visakhapatnam, Chennai, Haldai, Ennore, Paradip, Gandhidham, Surat, Canada, Dubai, Sharjah, Ajman, Abudhabi, UAE Middle East, Sohar Barka Muscat Oman


SURAT CHEMICAL TAG::

RXSOL-40-4023  is a high performance nitrite based closed circuit inhibitor.

RXSOL-40-4023  is a high performance nitrite based closed circuit inhibitor.

Nitrite based Corrosion Inhibitor for Water and Glycol Brine system is a multimetal corrosion inhibitor based on nitrate and othe organic compounds with special yellow metal corrosion inhibitor and antiscaling chemical that helps to prevent scale deposition or also removes adhering loose scale deposits from the heat transfer fluid system.

The disadvantages of not treating the closed circuit water can be equally troubling for the system operator:-
1. Leakage in PHE and AHU due to corrosion
2. Plugging and clogging of tubes and reduced flow rate
3. REduced heat transfer
4. Need of regular descalling that incurs shutdowns, loss of labor and time
5. Fouling of brine of chiller water

Chemical tratment removes dissolved oxygen that cause oxidation of metal to metal oxide i.e., Iron + Oxygen = Iron Oxide (Rust)

The chemical also contains a specific inhibitor to protect copper from corrosion and removes/prevents any sort of scale formation in the system.

Remarks

TREATMENT                         Feature

Sodium Nitrate                       Iron and Steel corrosion inhibitor. 800-2500 ppm recommended.

Molybdate                              Slows the growth of bacteria.

Tolyltriazole                            Copper corrosion Inhibitor.

Synthetic polymer                  Prevents hard scale built up.

Borax buffer                           Corrects the water pH (Maintain pH level between 8.5 to 9.2).

Silicates                               A common corrosion inhibitor used by automotive antifreeze suppliers is silicates. Silicates have the disadvantage of building up an insulating layer on components and are not recommended for industrial engines. Concentration should not exceed 25 ppm.

Note

Benefit :::

Zero or negligible loss of metal or corrosion Excellent heat transferability and flow rate No need of descaling closed circuit equipments Long and extended life of Water without fouling

Appearance

Colourless 

Odour

Odourless 

pH

11-12 approx

Boiling Point / Boiling Range

Not determined

Melting Point/Melting Range

N/A

Flash PointN/A

FlammabilityNon flammable

AutoflammabilityN/A

Explosive PropertiesN/A

Oxidising PropertiesN/A

Vapour PressureNot determined

Relative Density1.18 approx

Solubility in water Miscible

Solubility in other solvents Not determined

Partition coefficient and N-octanol/water ----------

Other DataNone
 

Engine Jacket Cooling or heating system, Chiller Water Circuit, Glycol Brine System, Hot Water or steam Circuit, Engine Coolant,Process chilling and heating system etc.

 

Engine Jacket Cooling or heating system, Chiller Water Circuit, Glycol Brine System, Hot Water or steam Circuit, Engine Coolant,Process chilling and heating system etc.

 

Description :::

Nitrite based Corrosion Inhibitor for Water and Glycol Brine system is a multimetal corrosion inhibitor based on nitrate and other organic compounds with special yellow metal corrosion inhibitor and antiscaling chemical that helps to prevent scale deposition or also removes adhering loose scale deposits from the heat transfer fluid system.

The disadvantages of not treating the closed circuit water can be equally troubling for the system operator:-
1. Leakage in PHE and AHU due to corrosion
2. Plugging and clogging of tubes and reduced flow rate
3. REduced heat transfer
4. Need of regular descaling that incurs shutdowns, loss of labour and time
5. Fouling of brine of chilled water

Chemical treatment removes dissolved oxygen that causes oxidation of metal to metal oxide i.e., Iron + Oxygen = Iron Oxide (Rust)

The chemical also contains a specific inhibitor to protect the copper from corrosion and removes/prevents any sort of scale formation in the system.

Application :::

Engine Jacket Cooling or heating system, Chiller Water Circuit, Glycol Brine System, Hot Water or steam Circuit, Engine Coolant, Process chilling and heating system etc.

DOSAGE :::

Nitrite base Corrosion Inhibitor for Water and Glycol Brine is normally fed continuously to the re-circulating closed system by injection dosing pump of dosed to the expansion tank. The amount of Nitrite base Corrosion Inhibitor for Water and Glycol Brine required inhibiting corrosion depends on the type of system and plant operating conditions. The specific dosage rates can be specified by the testing and given parameter.

Specification :::

Chemical Type Organic Chemical Compound

FormLiquid

Specific Gravity1.1+_0.05

pH12+_1 

Soluble in WaterSolubility Completey

Benefit :::

Zero or negligible loss of metal or corrosion Excellent heat transferability and flow rate No need of descaling closed circuit equipment Long and extended life of Water without fouling.


TREATMENT                         Feature

Sodium Nitrate                       Iron and Steel corrosion inhibitor. 800-2500 ppm recommended.

Molybdate                              Slows the growth of bacteria.

Tolyltriazole                            Copper corrosion Inhibitor.

Synthetic polymer                  Prevents hard scale built up.

Borax buffer                           Corrects the water pH (Maintain pH level between 8.5 to 9.2).

Silicates                                 A common corrosion inhibitor used by automotive antifreeze suppliers is silicates. Silicates have the disadvantage of building up an insulating layer on components and are not recommended for industrial engines. Concentration should not exceed 25 ppm.

Nitrite base Corrosion Inhibitor for Water and Glycol Brine is normally fed continuously to the re-circulating closed system by injection dosing pump of dosed to the expansion tank. The amount of Nitrite base Corrosion Inhibitor for Water and Glycol Brine required to inhibit corrosion depends on the type of system and plant operating conditions. The specific dosage rates can be specified by the testing and given parameter.

Copyright © 2021 Powered By SURAT CHEMICAL - All Rights Reserved