Scale and Corrosion Inhibitor for Cooling Water Treatment manufacturer and supplier in Mumbai, Muscat Oman, Fujairah UAE Middle East, Kolkata, Chennai, Visakhapatnam, Kandla, Gandhidham, Navi mumbai MIDC, Dubai, Sharjah, Ajman, Abudhabi
SURAT CHEMICAL TAG::
RXSOL-40-4022-210 is a high performance, low toxicity molybdate based cooling water corrosion inhibitor scientifically formulated for the treatment and protection of open and closed cooling water systems containing naturally soft or artificially soft water. RXSOL-40-4022-210 is an environmentally friendly, biodegradable scale and corrosion inhibitor that delivers superior results, protecting systems against the corrosion of steel, copper and brass, as well as containing an effective dispersant.
In addition RXSOL-40-4022-210 is stable to both chlorine and bromine at the levels normally found in cooling systems.RXSOL-40-RXSOL-40-4022 is a versatile molybdate-organophosphonate blend of scale and corrosion inhibitors for open recirculating cooling water systems. RXSOL-40-4022 is designed for systems with corrosive water (low hardness and/or low alkalinity). RXSOL-40-4022 will provide protection over a wide range of operating parameters.
Product Benefits:
- High performance, low toxicity molybdate corrosion inhibitor
- Excellent corrosion control for steel, copper and brass
- Contains an effective dispersant
- Low toxicity
- Environmentally friendly, biodegradable
- Designed specifically for use in natural or artificial soft water conditions
- Stable to chlorine and bromine at the levels normally found in cooling systems
- Controls the formation of scale
- Compatible with most cooling water treatment products
Product | Properties |
Form: | Liquid |
Colour: | Pale orange |
Odour: | Barely perceptible odour |
pH: | 12.0 – 14.0 |
Relative density: | Relative density: |
Solubility in water: | Miscible in all proportions |
Application & Dosage Information
RXSOL-40-4022-210 should be dosed to give 100 – 150 ppm for open systems and 1000 – 1500 ppm for closed systems.It is important when starting up a new system or re-starting an existing open cooling system apply a dose of 300 ppm.Enhanced corrosion control can be obtained by back blending 20 – 60 ppm hardness into the system.
NOTE – Always consider the cooling tower manufacturers control limits.
Testing & Control
Test for molybdate. Control to 5 ppm molydate for open systems and 100 ppm for closed systems. It is always advisable to carry out a ‘Control Of Substances Hazardous to Health’ (COSHH) assessment before use.