Skip to main content
Email suratchemical @ gmail.com:
Contact: 91 08069976684

MICRO BIOCIDE

MICRO BIOCIDE
SKU
RXSOL-40-4009-210
Supply Location::
Locations

MICRO BIOCIDE Cooling Water manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of MICRO BIOCIDE Cooling Water at a competitive price from us. We have ready stock of MICRO BIOCIDE Cooling Water in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.


SURAT CHEMICAL TAG::
Variations

Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system.

RXSOL-40-4009-210 is a high performance non-oxidising micro-biocide that uses the latest chemical technologies for the rapid and effective treatment of cooling water systems. RXSOL-40-4009-210 is a rapid acting micro-biocide developed for use in cooling water systems and is effective against Legionella bacteria, SRB’s, algi and fungi. RXSOL-40-4009-210 will also penetrate and disperse biofilm slimes making it an ideal cooling water treatment. RXSOL-40-4009-210 has an excellent environmental profile and is readily biodegradable.

MICRO BIOCIDE is a powerful microbiocide which will control a wide range of troublesome microbes in both open and closed water systems.

Remarks

How to control Algae growth in cooling towers, air conditioning cooling systems, and evaporative condensers?

 

RXSOL-40-4009-210  MICRO BIOCIDE Cooling Water RXSOL  is an organic chlorine releasing microbiocide which will effectively control the growth of algal slimes on cooling Water distribution decks, fill, and basins.

This product is recommended for use in industrial process cooling towers, air conditioning cooling systems, and evaporative condensers. It is particularly recommended for use in systems where algae growth is especially difficult to control.

Tag Identification

#MIcroBiocide_ManufacturerSupplier
#WaterTreatmentChemicals
#CorrosionInhibitor
#MarineChemical
#ShipHoldCleaningChemical
#TankCLeaner

Note

Product Benefits

  •     Rapid acting micro-biocide.
  •     Effective against Legionella, SRB 's, Algae, Fungi.
  •     Penetrates and disperses biofilm slimes.
  •     Excellent environmental profile (readily biodegradable).
  •     Readily monitored on site.


Product Properties


Appearance:  Colourless to Yellowish  Liquid
Odour          : Pungent
pH                :  6.5 -8

RXSOL-40-4009-210  is an organic chlorine releasing microbiocide which will effectively control the growth of algal slimes on cooling Water distribution decks, fill, and basins.
This product is recommended for use in industrial process cooling towers, air conditioning cooling systems, and evaporative condensers. It is particularly recommended for use in systems where algae growth is especially difficult to control.

RXSOL WATER TREATMENT CHEMICALS :

1. Sodium Chloride salt for softeners
2. Calcium hypochlorite 65-70%
3. Ferric Chloride 40% 
4. Sodium metabisulphite powder
5. Sodium Bromide.
6. Bromine Tablets suppliers in uae, Dubai, Sharjah.
7. Sodium Nitrite.
8. Sodium Molybdate
9. Phenolphthalein White
10. Caustic Soda liquid, Prills and flakes.
11.Ferrous Sulphate.
12.Poly Aluminium Chloride (PAC). 
13.Calcium Nitrate.
14.Calcium Chloride.
15.Sodium Sulphite.
16.Silica Sand and Gravel filtration media.
17.Birm and Anthracite.
18.Hydrazine Hydrate.
19.Carbohydrazide liquid and powder.
20.Cobalt Sulphate.
21.Zinc Chloride and Zinc Sulphate
22.Borax Pentahydrate and Borax Decahydrate
23.Citric acid solution and powder.
24.Sodium Hexameta phosphate. 

RXSOL-40-4009-210 should be dosed periodically at a rate of 75 - 150 ppm of the total system volume. In a badly fouled system an initial dosage rate of up to 250m1/m3 may be required which can be reduced once control is gained.In order to comply with Health & Safety recommendations RXSOL-40-4009-210 should be alternated with another non-oxidising or oxidizing biocide. It is always advisable to carry out a 'Control Of Substances Hazardous to Health' (COSHH) assessment before use.

Where MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 can be used?

For the control of microbial biofilms, bacteria, algae, and fungi, add MICRO BIOCIDE Cooling Water RXSOL-40-4009-210 to industrial recirculating water cooling towers, industrial recirculating closed loop water cooling systems, brewery pasteurizer and can warmer systems. Add MICRO BIOCIDE Cooling Water RXSOL-40-4009-210 at some point in the system to ensure uniform mixing.

Dose Ratio of 
MICRO BIOCIDE Cooling Water RXSOL-40-4009-210 
NOTE: Badly fouled systems should be cleaned before treatment.
 
INITIAL DOSE: if the system is initiating fouling then use 200 ml - 3 ltr of  MICRO BIOCIDE Cooling Water RXSOL-40-4009-210  for per 3000 to 5000 Ltr of water in the system.) Dose can be increased till optimum results.
 
WEEKLY CONTROL DOSE: When microbial control is evident, add 100 to 500 ml per MICRO BIOCIDE Cooling Water RXSOL-40-4009-210  for per 3000 to 5000 Ltr of water in the system
 
AIR WASHER SYSTEMS : Add to the air washer sump or chill water sump to insure uniform mixing, 200 ml  - 3 Ltr of MICRO BIOCIDE Cooling Water RXSOL-40-4009-210  for per 3000 to 5000 Ltr of water in the system, DOSE ration directly proportional of  contamination to control microbial biofilms, bacteria, fungi, and algae which cause fouling in industrial air washer systems.
 


Dose Ratio of MICRO BIOCIDE Cooling Water RXSOL-40-4009-210 for CONTINUOUS FEED METHOD  

Maintain this treatment level by adding a continuous feed of 100 ml to 1000 ml of MICRO BIOCIDE Cooling Water RXSOL-40-4009-210  per 1000 gallon of makeup water).

NOTE : Badly fouled systems must be cleaned before initial treatment.
 
 
 
Dose Ratio of MICRO BIOCIDE Cooling Water RXSOL-40-4009-210 for INDUSTRIAL WASTEWATER TREATMENT SYSTEMS AND SEWAGE SYSTEMS

INITIAL DOSE for Noticeably Fouled Condition: 500 ml - 4000 ml of MICRO BIOCIDE Cooling Water RXSOL-40-4009-210  per 3000 Ltr of water in the system. Repeat until control is achieved. Badly fouled systems should be cleaned before treatment is begun.

SUBSEQUENT DOSE: When microbial control is evident, add 100 ml  - 100 ml MICRO BIOCIDE Cooling Water RXSOL-40-4009-210  per 3000 Ltr of water in the system.

Copyright © 2021 Powered By SURAT CHEMICAL - All Rights Reserved